OVERVIEW
The MHQJ2 gripper is available in three dust cover materials: standard rubber, fluororubber and silicone rubber.
- Bore sizes: 10, 16, 20, 25 mm
- Auto switch capable
Specifications
Fluid | Air | ||
Operating pressure | Double acting | 0.1 to 0.6 MPa | |
Single acting | Normally open | 0.25 to 0.6 MPa | |
Normally closed | |||
Ambient and fluid temperature | –10 to 60°C | ||
Repeatability | ±0.01 mm | ||
Max. operating frequency | 180 c.p.m | ||
Lubrication | Not required | ||
Operating system | Double acting, Single acting | ||
Auto switch (Option) * | Solid state auto switch: D-M9N(V), D-M9P(V), D-M9B(V) |
Model
Operating system | Model | Cylinder bore (mm) | Note 1) Gripping force (Effective value) N | Opening/Closing stroke (mm) | Weight (g) | |
Double acting | MHQJ2-10D | 10 | 11 | 4 | 90 | |
MHQJ2-16D | 16 | 34 | 6 | 180 | ||
MHQJ2-20D | 20 | 42 | 10 | 340 | ||
MHQJ2-25D | 25 | 63 | 14 | 640 | ||
Single acting | Normally open | MHQJ2-10S | 10 | 7.8 | 4 | 90 |
MHQJ2-16S | 16 | 26 | 6 | 181 | ||
MHQJ2-20S | 20 | 33 | 10 | 342 | ||
MHQJ2-25S | 25 | 49 | 14 | 643 | ||
Normally closed | MHQJ2-10C | 10 | 7.8 | 4 | 90 | |
MHQJ2-16C | 16 | 26 | 6 | 181 | ||
MHQJ2-20C | 20 | 33 | 10 | 342 | ||
MHQJ2-25C | 25 | 49 | 14 | 643 |
Note 1) Values at the pressure of 0.5 MPa. Double acting is compatible with both external and internal gripping forces, while single acting and normally open external gripping force, and single acting and normally closed internal gripping force.
Note 2) Values excluding weight of auto switch